The VPInstruments VPFlowScope In-Line Flow Meter is ideal for point-of-use consumption measurement in compressed air systems. It measures mass flow, temperature, and pressure simultaneously and in both directions. It can be used for both in-line air flow and in-line gas flow measurement. With the VPFlowScope In-line can also check the efficiency of your distribution network as well as your true savings potential. It provides all the necessary data to make the right decisions.
The built-in display allows the user to see the real-time data. Combining this instrument with the built-in data logger enables recording for certain periods of time. When you install our VPStudio software on your PC, you can process data, print reports, and make smart analyses to find out where and how you can save money in your organization.
Overview and Features
Features
- Sizes and flow rates:
- 0.5″: 0.13 to 50 SCFM
- 1″: 0.54 to 150 SCFM
- 2″: 2.15 to 600 SCFM
- Air, Nitrogen, Oxygen, and Vacuum gas types
- Bi-directional sensitivity option available
- 250 PSI max pressure
- 140°F max temperature
- Modbus RS485 and single 4-20 mA industrial output
- 10-points calibration report included
- Optional datalogger available
- Inlet and outlet tubing kit included
Available configuration, accessories, delivery, and commissioning requirements will be confirmed during quotation.
Available specifications
| Size | 0.5", 1", 2" |
|---|---|
| Flow Range | 0.13 to 50 SCFM, 0.54 to 150 SCFM, 2.15 to 600 SCFM |
| Datalogger | No datalogger, Add datalogger |
| Tubing Kit | 0.5" tubing kit NPT, 1" tubing kit NPT, 2" tubing kit NPT |
| Sensing Options | Standard sensing (mass flow, pressure, temperature), Add bi-directional sensitivity option |