The Hedland API Oil / Caustic and Corrosive Liquid Flow Meter is a variable area flow meter with ranges from 0.1 to 1.0 GPM to 10 to 100 GPM. The meter provides direct readings and can be installed in any position. This rugged meter has a T316 stainless body, piston, and cone. It also features a 360° rotatable guard/scale, good viscosity stability, and is relatively insensitive to shock and vibration. It is rated to handle pressures of up to 6000 PSI (some models), temperatures up to 240°F, and has an accuracy of ±2% full scale.
Overview and Features
Features
- Temperature up to 240°F
- Accuracy ±2% full scale
- T316 Stainless body, piston, and cone
- 360° rotatable guard/scale
- Easy-to-read linear scale
- Repeatability ±1%
Available configuration, accessories, delivery, and commissioning requirements will be confirmed during quotation.
Available specifications
| Nominal Port Size | 1/4", 1/2", 3/4", 1", 1-1/4", 1-1/2" |
|---|---|
| Flow Media | API - Oil .876 (S.G.), Liquids 1.0 (S.G.) |
| Thread Type | NPTF, BSPP |
| Body Material | Stainless steel, Stainless steel; CRN registered |
| Flow Range | 0.1 to 1.0 GPM, 0.2 to 2.0 GPM, 0.5 to 5.0 GPM, 1 to 10 GPM, 1 to 15 GPM, 2 to 20 GPM, 3 to 30 GPM, 4 to 40 GPM, 5 to 50 GPM, 10 to 75 GPM, 10 to 100 GPM |
| Options | None, Hostile environment, 1 micro switch, 2 micro switches, 1 reed switch, normally open, 1 reed switch, normally closed, 2 reed switches, normally open, 2 reed switches, normally closed, MR flow transmitter |